LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON K3HB-VLC-FLK3ET11 User's Manual PDF
Product model: K3HB-VLC-FLK3ET11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-VLC-FLK3ET11 PDF.
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-VLC-FLK3ET11
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-VLC-FLK3ET11 PDF.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2 K3HB-VLC-FLK3ET11 PDF.
CE marking and cUL certified (K8AC-H2@@@). Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External poweer 80mA DC12V K3HB-VLC-FLK3ET11 Manual.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input OMRON User's Manual.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse OMRON User's Manual.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50kHzTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) OMRON User's Manual.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated fromm the start of operation K3HB-VLC-FLK3ET11 User's Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-FLK3ET11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E1 AC100-240
Category: external supply 100mA DC5V typ
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V typ
OMRON
Load sensor, mV instrument
K3HB-VLC-L2ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-L2ET11 AC/DC24
Category: external supply 100mA DC5V typ