OMRON K3HB-VLC-FLK1ET11 Communications Manual PDF
Product model: K3HB-VLC-FLK1ET11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-VLC-FLK1ET11 PDF.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-VLC-FLK1ET11
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-VLC-FLK1ET11 PDF.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2 K3HB-VLC-FLK1ET11 PDF.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operatting Functions (Overcurrent, Open,
phase, and Reverse-phase) OMRON Communications Manual K3HB-VLC-FLK1ET11 Manual.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON Communications Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AAC/DC24V K3HB-VLC-FLK1ET11 Communications Manual.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, ccan switch the green / Red 2 kinds of color display K3HB-VLC-FLK1ET11 Manual.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event transport