LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON K3HB-VLC-E1 User's Manual PDF
Product model: K3HB-VLC-E1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Detect errors in motors and other equipment,
through current changes.
Monitor for overcurrents and undercurrents,
simultaneously with one Relay.
Monitor AC or DC currents with one Relay K3HB-VLC-E1 PDF.
Use with commercially available CTs (CT secondary side: 0 to 1 A or 0 to 5 A).
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires K3HB-VLC-E1
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability K3HB-VLC-E1 PDF. High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously K3HB-VLC-E1 PDF.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sennsor included in the Unit K3HB-VLC-E1 Manual.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power OMRON User's Manual.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor OMRON User's Manual.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring OMRON User's Manual.
Incorrect voltage wiring detection. Wiring distance: Standard usage, Wiring cable: 50 m max. Sensing Bands: 10 m max.
Disconnection detection: Supported.
Socket terminals: Screw Terminal Block P2RF-08/-08-E.
Reliable Sensitive Liquid Sensors,
for Stable Detection of Liquid K3HB-VLC-E1 User's Manual.
Chemicals with Low Conductivity,
and Water Leakage.
New models available that are compatible with Push,
In Plus Terminal Block Sockets.
UL listed when used with Push-In Plus Terminal,
Block Sockeets K3HB-VLC-E1 Manual.
Sensor disconnection detection (K7L-AT50D@/-UD@).
Models for long-distance wiring to 400 m.
Ribbon Electrode Bands and Point Sensors available.