OMRON K3HB-SSD-CPAC12 Communications Manual PDF
Product model: K3HB-SSD-CPAC12
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays K3HB-SSD-CPAC12 PDF.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits K3HB-SSD-CPAC12
Manual or automatic resetting with the same Relay. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-SSD-CPAC12 PDF.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-SSD-CPAC12 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for moniitoring the operation trend K3HB-SSD-CPAC12 Manual.
External event input can be applied toRated primary current: 50 A.
Rated secondary current: Special output OMRON Communications Manual.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously OMRON Communications Manual.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power OMRON Communications Manual.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
AAlarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor K3HB-SSD-CPAC12 Communications Manual.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K3HB-SSD-CPAC12 Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.