LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON K3HB-HTA-FLK1AT11 Communications Manual PDF
Product model: K3HB-HTA-FLK1AT11
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V K3HB-HTA-FLK1AT11 PDF.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation K3HB-HTA-FLK1AT11
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset K3HB-HTA-FLK1AT11 PDF.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits K3HB-HTA-FLK1AT11 PDF.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring OMRON Communications Manual.
Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple/Pt100.
Setting unit (setting range): Unit: 1°C/°F (0 to 399°C/°F).
Compact and Slim Relay Ideal for OMRON Communications Manual.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,,
abnormal temperatures can be monitored K3HB-HTA-FLK1AT11 Manual.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input OMRON Communications Manual.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Model: OCGR-H (51G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributtaries K3HB-HTA-FLK1AT11 Communications Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-HTA-FLK1AT11 Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Temperature panel
K3HB-HTA-1 AC/DC24
OMRON Temperature panel K3HB-HTA-1 AC/DC24
Type of input: platinum resistance / the
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Temperature panel
K3HB-HTA-1 AC100-240
OMRON Temperature panel K3HB-HTA-1 AC100-240
Type of input: platinum resistance / the
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L1AT11 AC/DC24
Type of input: platinum resistance / the