Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment K2CM-Q1LS PDF.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A)
K2CM-Q1LS
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator K2CM-Q1LS PDF.
Inputs are isolated from the power supply. Cable length: 3 m.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported K2CM-Q1LS PDF. )
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements K2CM-Q1LS Manual.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power OMRON Communications Manual.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost OMRON Communications Manual. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage OMRON Communications Manual.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay conttact: HH; PASS1c, H, L, LL: each 1a K2CM-Q1LS Communications Manual.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kindds of color display K2CM-Q1LS Manual.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the most up to 50kHz high speed pulse