LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON K2CM-4HA Communications Manual PDF
Product model: K2CM-4HA
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise K2CM-4HA PDF.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors K2CM-4HA Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three K2CM-4HA PDF.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K2CM-4HA PDF.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Communications Manual K2CM-4HA Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Models: OVGR (64).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched OMRON Communications Manual.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system OMRON Communications Manual.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internnal tributaries K2CM-4HA Communications Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K2CM-4HA Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Motor Protective Relay
K2CM-Q4H
OMRON Motor Protective Relay K2CM-Q4H
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q4MA
OMRON Motor Protective Relay K2CM-Q4MA
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q2H
OMRON Motor Protective Relay K2CM-Q2H
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q2MV
OMRON Motor Protective Relay K2CM-Q2MV
Time specification: Instantaneous type.