Product model: H7CN-BLN
Name: Digital Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Supply voltage: 12 VDC.
Control output: Contact output, SPDT (time-limit SPDT).
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications H7CN-BLN PDF.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0 H7CN-BLN
Start signal control for the H3DK-M. Display type: DOWN display timer (decrements form the set time to 0).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC H7CN-BLN PDF.
Rated time: 1 min to 99 h 59 min(See note 3.).
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series verrsion cover a wide range of rated times; 9 H7CN-BLN Manual. 999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements H7CN-BLN PDF.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Type: H5CX-L series.
Time specifications: 0 OMRON User's Manual. 001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON User's Manual.
External connections: 8-pin socket OMRON User's Manual.
Input: Signal, Reset (NPN innput) H7CN-BLN User's Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h599 H7CN-BLN Manual. 9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m.
Related products
OMRON
Solid-state Counter
H7CN-YHNM
OMRON Solid-state Counter H7CN-YHNM
Classification: Preset Counter. Input s
OMRON
Solid-state Counter
H7CN-TXL
OMRON Solid-state Counter H7CN-TXL
Classification: Totalizing Counter. Inp
OMRON
Solid-state Counter
H7CN-BHN
OMRON Solid-state Counter H7CN-BHN
Classification: Preset Counter. Input s
OMRON
Solid-state Counter
H7CN-XHN
OMRON Solid-state Counter H7CN-XHN
Classification: Preset Counter. Input s