OMRON GRT1-CT1-1 OPERATION MANUAL PDF
Product model: GRT1-CT1-1
Name: CompoBus/S Module
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes GRT1-CT1-1 PDF.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short GRT1-CT1-1
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures GRT1-CT1-1 PDF.
Error detection level can be easily seet with a switch GRT1-CT1-1 Manual.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV) GRT1-CT1-1 PDF.
The G3PF-2@@B-@@@ Series is UL certified. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 30 A at 180 to 400 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink OMRON OPERATION MANUAL.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load OMRON OPERATION MANUAL.
Certified by UL, CSA, and VDE (reinforced insulation). Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 11 GRT1-CT1-1 OPERATION MANUAL. ).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays OMRON OPERATION MANUAL.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a sufffix of“-VD”) GRT1-CT1-1 Manual.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix).
Related products
OMRON
CompoNet Communications Unit
GRT1-OD4
OMRON CompoNet Communications Unit GRT1-OD4
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-ID4
OMRON CompoNet Communications Unit GRT1-ID4
Name: Slice I/O Units Digital I/O Units
OMRON
System Units
GRT1-PC8-1
OMRON System Units GRT1-PC8-1
Name: System Units I/O Power Feed Unit.
OMRON
System Units
GRT1-TBR
OMRON System Units GRT1-TBR
Name: System Units Turnack Units. Sp