LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON E5CN-HQ2HH03D-FLK Basic Type PDF
Product model: E5CN-HQ2HH03D-FLK
Name: OMRON E5CN-HQ2HH03D-FLK Manual E5CN-HQ2HH03D-FLK Basic Type
Brand: OMRON
Sort: Basic Type
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 8m E5CN-HQ2HH03D-FLK PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-HQ2HH03D-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Name: Tape reflector E5CN-HQ2HH03D-FLK PDF.
Directional angle: 30° min.
Ambient operating temperature range: 0 to 40°C.
Ambient storage temperature range: -40 to 70°CC E5CN-HQ2HH03D-FLK Manual.
Ambient operating humidity range: 35% to 85%.
Ambient storage humidity range: 35% to 85%.
Degree of protection: IEC IP67.
Accessories: --. Case color: Black E5CN-HQ2HH03D-FLK PDF.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: -- OMRON Basic Type.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 OMRON Basic Type. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controllerr (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON Basic Type E5CN-HQ2HH03D-FLK Basic Type.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-HQ2HH03D-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.