Classification: Exclusive Models.
Description: Used for measuring surface temperatures.
Temperature range (See note 3.): -50°C to 250°C .
Element type: Pt100 E5AN-HTAA2HHBFM-500 PDF.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 39.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E5AN-HTAA2HHBFM-500
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AN-HTAA2HHBFM-500 PDF. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output E5AN-HTAA2HHBFM-500 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: - OMRON User's Manual.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5AN-HTAA2HHBFM-500 Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON User's Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further perrformance improvement E5AN-HTAA2HHBFM-500 User's Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AN-HTAA2HHBFM-500 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.