LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON E5AC-QX4ASM-011 lnstruction Manual (RS-485 CompoWay/F) PDF
Product model: E5AC-QX4ASM-011
Name: TOtal counter
Brand: OMRON
Sort: RS-485 CompoWay/F lnstruction Manual
File language: English
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- E5AC-QX4ASM-011 PDF.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK E5AC-QX4ASM-011
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 E5AC-QX4ASM-011 PDF. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AC-QX4ASM-011 PDF.
Preventive maintenance for relays iin the Temperature,
Controller using a Control Output ON/OFF Counter E5AC-QX4ASM-011 Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 OMRON lnstruction Manual. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Large display + status indicator.
Add action mode indicator (ON/D L ON) and teaching status indicator light,
Status at a glance.
Connection type: connector.
Output mode: NPN output OMRON lnstruction Manual. Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON lnstruction Manual.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furrther performance improvement E5AC-QX4ASM-011 lnstruction Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5AC-QX4ASM-011 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5AC-QX4DSM-008
OMRON Digital temperature controller E5AC-QX4DSM-008
Size: 96 x 96mm. Control output 1: volt
OMRON
Digital Temperature Controller
E5AC-QX3DSM-808
OMRON Digital Temperature Controller E5AC-QX3DSM-808
Control output 1: Voltage output. Contr
OMRON
Digital temperature controller
E5EC-RR2ASM-011
OMRON Digital temperature controller E5EC-RR2ASM-011
Size: 48 x 96mm. Control output 1: rela
OMRON
Digital temperature controller
E5AC-RR4ASM-011
OMRON Digital temperature controller E5AC-RR4ASM-011
Size: 96 x 96mm. Control output 1: rela