Model: C500-CN222N.
Cable length 2m.
CV Series C Series Expansion ← → I / O device CPU Connecting cable(Vertical-wired)Model: C500-BC031(3G2A5-BC031) CP1E-N40DT1-A PDF.
3 slots(3 linkable slots).
Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced
CP1E-N40DT1-A
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CP1E-N40DT1-A PDF.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS1 CPU Bus Unit.
Product name:SPU Unit,
(High-speed Data Storage Unit).
Specifications: PC Card slot,
1 PC Card Type II slot Insert an,
OMRON HMC-EF@@@ to use the Memory Card;
Ethernet (LAN) port, 2 port(10/100BASE-TX) CP1E-N40DT1-A PDF.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.70A; 26V, --.
Standards: UC1, CE.
High-speed Collection of System Data.
The CPU Unit can collect large amounts,
of process data, operation data,
inspection data, and other controlled system,
data quickly and automatically save the data,
in external storage media as CSV files OMRON REFERENCE MANUAL. Model: C200H-BC051-V2.
No. of I/O slots: 5 slots.C200H A Backplane I/O Mounting Bracket For 5 Slots C200H-ATT53.Unit type: CS1 Special I/O Units OMRON REFERENCE MANUAL.
Product name: Isolated-type,
Analog Output Unit CP1E-N40DT1-A Manual.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block OMRON REFERENCE MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1E-N40DT1-A REFERENCE MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40DT1-A Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.