Product model: CJ1W-PDC15
Name: Programmable Terminals
Brand: OMRON
Sort: Installation Guide
File language: English
Output method: Relay.
Inputs: ---.
Outputs: 8.Specifications: Optical cable(H-PCF cable).Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots CJ1W-PDC15 PDF.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No CJ1W-PDC15
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE CJ1W-PDC15 PDF.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Model: C200H-DA002.
Input points: 4.
Voltage input: –10 to 10V.
Current input: 4 to 20 mA.Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8; Outputs, 6;
Output type: Transistor (sinking) CJ1W-PDC15 PDF.
Program capaacity: 8K steps CJ1W-PDC15 Manual.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient OMRON Installation Guide.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range) OMRON Installation Guide.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note).Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 OMRON Installation Guide.
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connecction: Removable terminal block CJ1W-PDC15 Installation Guide.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-PDC15 Manual.
Analog Output Units for converting binary ,
data into analog output signals.
Related products
OMRON
CJ-series Power Supply Unit
CJ1W-PA202
OMRON CJ-series Power Supply Unit CJ1W-PA202
Power supply voltage: 100 to 240VAC. O
OMRON
Output Units
CJ1W-OD203
OMRON Output Units CJ1W-OD203
Unit type: CJ1 Basic I/O Units. Produ
OMRON
ID Sensor Unit
CJ1W-V600C12
OMRON ID Sensor Unit CJ1W-V600C12
Type: CS Special I/O Unit. Connected