Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection CJ1M-CPU11 PDF.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CJ1M-CPU11
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CJ1M-CPU11 PDF. vName: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes CJ1M-CPU11 PDF.
Standards: UC1, N, L, CE.
Redundaant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CJ1M-CPU11 Manual. Unit type: CS1 CPU Bus Unit.
Product name:SPU Unit,
(High-speed Data Storage Unit).
Specifications: PC Card slot,
1 PC Card Type II slot Insert an,
OMRON HMC-EF@@@ to use the Memory Card;
Ethernet (LAN) port, 2 port(10/100BASE-TX) OMRON SYSTEM MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.70A; 26V, --.
Standards: UC1, CE.
High-speed Collection of System Data.
The CPU Unit can collect large amounts,
of process data, operation data,
inspection data, and other controlled system,
data quickly and automatically save the data,
in external storage media as CSV files OMRON SYSTEM MANUAL. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-232C ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave OMRON SYSTEM MANUAL.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.28A; 224V,-- CJ1M-CPU11 SYSTEM MANUAL.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CJ1M-CPU11 Manual.