LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Manual Download
OMRON 3G3MX2-AB022-ZV1 Quick Reference Guide PDF
Product model: 3G3MX2-AB022-ZV1
Name: Linear Sensor lndicator
Brand: OMRON
Sort: Quick Reference Guide
File language: English
Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 1.25 square mm, 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line 3G3MX2-AB022-ZV1 PDF.
Try to be close to the transducer for connection. Specification: three phase 200V.
Power: 2.2KW.
Maximum output voltage: three phase input voltage 3G3MX2-AB022-ZV1
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling: forced air cooling.
Weight: 1.9kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ 3G3MX2-AB022-ZV1 PDF.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3MX2-AB022-ZV1 PDF.
Covers the special features of the fan pumpp class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice OMRON Quick Reference Guide 3G3MX2-AB022-ZV1 Manual. Inverter input power: 3 phase / single phase AC200V.
Weight: 2.6KG.
Standard applicable line diameter: 3.5 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor OMRON Quick Reference Guide. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.3KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor OMRON Quick Reference Guide. Function name: single phase 200V.
Power: 0.75KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.

Mechanical automation concept 3G3MX2-AB022-ZV1 Quick Reference Guide.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G3MX2-AB022-ZV1 Manual. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.