OMRON K8AC-H21PN-FLK datasheet PDF
Product model: K8AC-H21PN-FLK
Name: Digital Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Rated primary current: 400 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported K8AC-H21PN-FLK PDF. )
Power and current can be measured simultaneously K8AC-H21PN-FLK
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy K8AC-H21PN-FLK PDF.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications K8AC-H21PN-FLK PDF.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Product: Replacement Dischargers (set of 5).
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated fromm the start of operation K8AC-H21PN-FLK datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AC-H21PN-FLK datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.