LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K8AB-VW2 AC200/230V datasheet PDF
Product model: K8AB-VW2 AC200/230V
Name: Single-phase Voltage Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AB-VW2 AC200/230V PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AB-VW2 AC200/230V
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-VW2 AC200/230V PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-VW2 AC200/230V PDF.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K8AB-VW2 AC200/230V datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-VW2 AC200/230V datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS1 AC200/230V
Measuring voltage: 6 to 60 mV AC/DC, 10
OMRON
Single-phase Voltage Relay
K8AB-VW3 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW3 AC200/230V
Measuring voltage: 20 to 200 V AC/DC, 30
OMRON
Single-phase Current Relay
K8AB-AS2 AC200/230V
OMRON Single-phase Current Relay K8AB-AS2 AC200/230V
Measuring current: 0.1 to 1 A AC/DC, 0.5
OMRON
Single-phase Voltage Relay
K8AB-VW1 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW1 AC200/230V
Measuring voltage: 6 to 60 mV AC/DC, 10