LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K8AB-VW2 AC100/115V datasheet PDF
Product model: K8AB-VW2 AC100/115V
Name: Single-phase Voltage Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit K8AB-VW2 AC100/115V PDF.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K8AB-VW2 AC100/115V
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A K8AB-VW2 AC100/115V PDF.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements K8AB-VW2 AC100/115V PDF.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protectioon and coordination of digital DCR K8AB-VW2 AC100/115V datasheet.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme K8AB-VW2 AC100/115V datasheet.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.
Related products
OMRON
Single-phase Voltage Relay
K8AB-VS3 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS3 AC100/115V
Measuring voltage: 20 to 200 V AC/DC, 30
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS1 AC100/115V
Measuring voltage: 6 to 60 mV AC/DC, 10
OMRON
Single-phase Voltage Relay
K8AB-VS2 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS2 AC100/115V
Measuring voltage: 1 to 10 V AC/DC, 3 to
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW2 AC200/230V
Measuring voltage: 1 to 10 V AC/DC, 3 to