LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K8AB-AS2 AC/DC24V datasheet PDF
Product model: K8AB-AS2 AC/DC24V
Name: Single-phase Current Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K8AB-AS2 AC/DC24V PDF.
Action determine the color, can switch the green / Red 2 kinds of color display K8AB-AS2 AC/DC24V
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily setMeasuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC K8AB-AS2 AC/DC24V PDF.
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed K8AB-AS2 AC/DC24V PDF.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Product: Straight Bar Nozzle; 100 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase controol, and cyclic control K8AB-AS2 AC/DC24V datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K8AB-AS2 AC/DC24V datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-B1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B1 AC/DC24V
Category: external supply 100mA DC10V.
OMRON
Frequency/Rate Meter
K3MA-F AC/DC24V
OMRON Frequency/Rate Meter K3MA-F AC/DC24V
Input type: Rotary pulse. Supply voltag
OMRON
Single-phase Current Relay
K8AB-AS1 AC/DC24V
OMRON Single-phase Current Relay K8AB-AS1 AC/DC24V
Measuring current: 2 to 20 mA AC/DC, 10
OMRON
Time interval table
K3HB-PNB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-L2AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ