OMRON K3HB-XAD-FLK3AT11 AC/DC24 datasheet PDF
Product model: K3HB-XAD-FLK3AT11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Ideal for Monitoring 3-phase Power Supplies.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XAD-FLK3AT11 AC/DC24 PDF.
World-wide power specifications supported by one unit K3HB-XAD-FLK3AT11 AC/DC24
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL) K3HB-XAD-FLK3AT11 AC/DC24 PDF.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points K3HB-XAD-FLK3AT11 AC/DC24 PDF.
Pulse interval measurementSolid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: transistor; - NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High sspeed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAD-FLK3AT11 AC/DC24 datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inpuut can be applied to a variety of measurement and identification situations K3HB-XAD-FLK3AT11 AC/DC24 datasheet.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm
Related products
OMRON
Time interval table
K3HB-PNB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PNB-AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L1AT11 AC/DC24
Type of input: platinum resistance / the