OMRON K3HB-VLC-L2ET11 AC100-240 datasheet PDF
Product model: K3HB-VLC-L2ET11 AC100-240
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function K3HB-VLC-L2ET11 AC100-240 PDF.
Simple temperature measurements with Temperature Sensor included in the Unit K3HB-VLC-L2ET11 AC100-240
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-VLC-L2ET11 AC100-240 PDF.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage K3HB-VLC-L2ET11 AC100-240 PDF.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-L2ET11 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-L2ET11 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Rotating pulse meter
K3HB-RNB-FLK1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input typ