OMRON K3HB-VLC-FLK3ET11 AC/DC24 datasheet PDF
Product model: K3HB-VLC-FLK3ET11 AC/DC24
Name: Load sensor, mV instrument
Brand: OMRON
Sort: PDF datasheet
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element K3HB-VLC-FLK3ET11 AC/DC24 PDF.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-VLC-FLK3ET11 AC/DC24
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-VLC-FLK3ET11 AC/DC24 PDF.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below K3HB-VLC-FLK3ET11 AC/DC24 PDF.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1a, DC; closed circuit 110V 15A 1C 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
Relay control output for circuit breaker switching.
Quality: about 0.6kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.

Power supply voltage: AC/DC24V K3HB-VLC-FLK3ET11 AC/DC24 datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Meeasurement of wide range of pulse interval time K3HB-VLC-FLK3ET11 AC/DC24 datasheet.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement