File language: English
Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-PNB-CPAC21 AC/DC24V PDF.
Output relay can be switched between normally open and normally closed K3HB-PNB-CPAC21 AC/DC24V
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: DC current input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-PNB-CPAC21 AC/DC24V PDF.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-PNB-CPAC21 AC/DC24V PDF.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-PNB-CPAC21 AC/DC24V datasheet.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PNB-CPAC21 AC/DC24V datasheet.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Rotating pulse meter
K3HB-RPB-CPAC21 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-CPAC21 AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PPB-CPAC21 AC/DC24V
OMRON Time interval table K3HB-PPB-CPAC21 AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PNB-CPAC11 AC100-240
OMRON Time interval table K3HB-PNB-CPAC11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PNB-CPAC11 AC/DC24V
OMRON Time interval table K3HB-PNB-CPAC11 AC/DC24V
Input type: NPN/ voltage pulse input typ