OMRON K2CU-P2-B datasheet PDF
Product model: K2CU-P2-B
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2 K2CU-P2-B PDF. 0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side) K2CU-P2-B
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg K2CU-P2-B PDF.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time K2CU-P2-B PDF.
The control power of the relay is not needed, which avoids the trouble of wiring.
Type: Medium-sensitivity models.
Sensed current: 100 mA/200 mA (switchable).
Type: High-speed models.
Operating time: Less than 0.1 s.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Type of input: AC current input.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The mmost suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CU-P2-B datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gaauge for monitoring the operation trend K2CU-P2-B datasheet.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type
Related products
OMRON
Heater Element Burnout Detector
K2CU-P0.5A-A
OMRON Heater Element Burnout Detector K2CU-P0.5A-A
Control supply voltage: 100/200 VAC Wit
OMRON
Heater Element Burnout Detector
K2CU-F20A-DGS
OMRON Heater Element Burnout Detector K2CU-F20A-DGS
Control supply voltage: 110 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F10A-F
OMRON Heater Element Burnout Detector K2CU-F10A-F
Control supply voltage: 220 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-P1A-B
OMRON Heater Element Burnout Detector K2CU-P1A-B
Control supply voltage: 110/220 VAC Wit