LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON K2CU-P1A-B datasheet PDF
Product model: K2CU-P1A-B
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Appearance: ADR shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt K2CU-P1A-B PDF.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16 K2CU-P1A-B7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0 K2CU-P1A-B PDF. 1 1000.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed K2CU-P1A-B PDF.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordination of digital DCR.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any time.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ traansistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL) K2CU-P1A-B datasheet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the ccolor, can switch the green / Red 2 kinds of color display K2CU-P1A-B datasheet.
Measurement of 50kHz high speed pulse.
Rotary encoder and all kinds of ON/OFF pulse signal
Related products
OMRON
Heater Element Burnout Detector
K2CU-F40A-FGS
OMRON Heater Element Burnout Detector K2CU-F40A-FGS
Control supply voltage: 220 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-P1A-B
OMRON Heater Element Burnout Detector K2CU-P1A-B
Control supply voltage: 110/220 VAC Wit
OMRON
Heater Element Burnout Detector
K2CU-P2A-A
OMRON Heater Element Burnout Detector K2CU-P2A-A
Control supply voltage: 100/ 200 VAC Wi
OMRON
Heater Element Burnout Detector
K2CU-F40A-D
OMRON Heater Element Burnout Detector K2CU-F40A-D
Control supply voltage: 110 VAC With vo