LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON GRT1-IA4-1 datasheet PDF
Product model: GRT1-IA4-1
Name: CompoNet Communications Unit
Brand: OMRON
Sort: PDF datasheet
File language: English
Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 outputs NPN.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system GRT1-IA4-1 PDF.
A wide variety of CompoNet Slave Units,
contribute to system size reduction GRT1-IA4-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Terminal (wire connection): Screw terminal.
Applicable output load: AC load GRT1-IA4-1 PDF.
Zero cross function: Yes.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals GRT1-IA4-1 PDF. ).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phasee heaters GRT1-IA4-1 datasheet.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) GRT1-IA4-1 datasheet.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
Related products
OMRON
CompoNet Communications Unit
GRT1-CT1-1
OMRON CompoNet Communications Unit GRT1-CT1-1
Name: Slice I/O Units Counter Units.
OMRON
CompoNet Communications Unit
GRT1-OD4-1
OMRON CompoNet Communications Unit GRT1-OD4-1
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-TS2PK
OMRON CompoNet Communications Unit GRT1-TS2PK
Name: Slice I/O Units Temperature Input
OMRON
CompoNet Communications Unit
GRT1-IA4-1
OMRON CompoNet Communications Unit GRT1-IA4-1
Name: Slice I/O Units Digital I/O Units