Product model: GRT1-END
Name: System Units
Brand: OMRON
Sort: PDF datasheet
File language: English
Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 45 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications GRT1-END PDF.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents GRT1-END (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Type: Standard.
Latching lever (Test switch): NO.
Rated input voltage: DC, 48.
Applicable model: G2RV-SR700/500 AC/DC48V, G2RV-SR700/500 AC100V,
G2RV-SR700/500 AC110V, G2RV-SR700/500 AC200V, G2RV-SR700/500 AC230V GRT1-END PDF.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated GRT1-END PDF.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle controll GRT1-END datasheet.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control GRT1-END datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
Related products
OMRON
System Units
GRT1-PD8
OMRON System Units GRT1-PD8
Name: System Units I/O Power Feed Unit.
OMRON
CompoNet Communications Unit
GRT1-ID8-1
OMRON CompoNet Communications Unit GRT1-ID8-1
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-CRT
OMRON CompoNet Communications Unit GRT1-CRT
Name: CompoNet Communication Unit. Spec
OMRON
CompoNet Communications Unit
GRT1-OD4-1
OMRON CompoNet Communications Unit GRT1-OD4-1
Name: Slice I/O Units Digital I/O Units