OMRON G3J-S405BL DC12-24 datasheet PDF
Product model: G3J-S405BL DC12-24
Name: Soft-start Solid State Contactors
Brand: OMRON
Sort: PDF datasheet
File language: English
Cable with connector (1 to 2) /G79-I_-_-D1,
G79-O_-_-D1, G79-M_-_-D1.
Size: A, 500mm; B, 250mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V G3J-S405BL DC12-24 PDF.
Input rated voltage: DC5V.
Insulation mode: three end two-way photoelectric switch G3J-S405BL DC12-24
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input G3J-S405BL DC12-24 PDF. Insulation mode: three end two-way switch coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC5 240V ~ DC5 1.0A ~ 100V.
Input rated voltage: DC24V.
With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance.
Can achieve AC240V or DC100V, 1A load switch G3J-S405BL DC12-24 PDF.
Output open circuit leakage current: 10 A.
Input / output voltage resistance AC2500V.
Built in input resistance and over voltage absorbing circuit.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Name: Slice I/O Units; Digital I/O Units.
Specifications: 8 inputs NPN.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Safety outputs: Instantaneous, DPST-NO; OFF-delayed, DPST-NO.
AAuxiliary outputs: 1 (Solid-state) G3J-S405BL DC12-24 datasheet.
Max. OFF-delay time: 30 s.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simpple wiring using screw-less terminals G3J-S405BL DC12-24 datasheet.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input.