E3Z-T87-G0 detection methods: the firing pattern.
Connection: socket type (M8).
Detection range: 30m.
Output mode: PNP output.
Achieve small, long distance, save electricity and
Standard type of photoelectric sensor for energy saving
Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control E5AZ-R3HMTD PDF.
Outputs(control/transfer): 2 (pulse + pulse/current)
E5AZ-R3HMTD
Optional functions: Auxiliary outputs (SUB), 4; Event inputs, 2;
Serial communications, RS-485.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller E5AZ-R3HMTD PDF.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Temperature Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-232C.
Event input: None E5AZ-R3HMTD PDF.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AZ-R3HMTD datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AZ-R3HMTD datasheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.