Type: Shielded.
Appearance: Screw, M10 × 22 mm.
Sensing distance: 2 mm.
Repeat accuracy: 2 μm.
Cable specification: With Protective Spiral Tube.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application E2B-M18KN10-M1-B1 PDF. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads
E2B-M18KN10-M1-B1
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening with,
fine positioning to maximize variations E2B-M18KN10-M1-B1 PDF.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Ordering Information.
Sensing method: Reflective.
Sensor with an Adjustable Sensing.
Distance of 0.3 to 3 m Under Stable.
Operation without Background.
Interference.
Ensures a stable operating range with minimal,
side-lobe areas E2B-M18KN10-M1-B1 PDF.
Built-in unstable operation check function allows,
easy adjustment to a proper mounting direction.
Mono-block construction with a sensor, power,
supply, and terminals ensures easy wiring.
Incorporates synchronous selector and reference,
pulse I/O terminals ideal for parallel-operation use,
without mutual interference. E32-T14L type: standard type; standard,
Specialty: 3 cylinder side,
Shape / detection distance (mm): 600; 460; 300 (120),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsSize: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes thee process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2B-M18KN10-M1-B1 datasheet.
Through the infrared port can be carried out from the frront of the communication E2B-M18KN10-M1-B1 datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.