Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4C-1224 PDF. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4C-1224
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4C-1224 PDF.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Shaft.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving D4C-1224 PDF.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Lock method: Solenoid lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
Without indicator 1NC/1NO+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4C-1224 datasheet.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4C-1224 datasheet.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.