I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).Number of outputs: 16 pts.
Input Voltage: 250 VAC, 24 VAC.
Max Switching Current: 2 Amps.
Common Type: Shared.Model : CV500-CIF01.
Port for peripherals (6m) 25-pin CRT1-VDA02SD PDF. CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 18; Output, 12
CRT1-VDA02SD
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet CRT1-VDA02SD PDF.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Model: C500-CE401.
Solder pin connector cover 40PModel: C200H-ID501.
No. of inputs: 32 pts.
Specifications: 5 VDC.Model: C200H-MP831.
Description: EPROM, 8K words, no clock CRT1-VDA02SD PDF. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems CRT1-VDA02SD datasheet.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CRT1-VDA02SD datasheet.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.