File language: English
A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required. No PC card is provided with the Unit.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave CP1E-N40SDR-A PDF CP1E-N40SDR-A
No. of unit numbers allocated: 1.
Current consumption : 5V, 0 CP1E-N40SDR-A PDF. 36A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CP1E-N40SDR-A PDF. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Thermocouple: R, S, K, J, T, L, B.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±1°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Curreent consumption: 5V, 0 CP1E-N40SDR-A datasheet. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CP1E-N40SDR-A datasheet.
All inputs are isolated.
Related products
OMRON
CP1E CPU Units
CP1E-NA20DR-A
OMRON CP1E CPU Units CP1E-NA20DR-A
Product name: NA-type CPU Units with 20
OMRON
CP1E CPU Units
CP1E-N60S1DT1-D
OMRON CP1E CPU Units CP1E-N60S1DT1-D
Product name: NS1- type CPU Units with
OMRON
CP1E CPU Units
CP1E-E30SDR-A
OMRON CP1E CPU Units CP1E-E30SDR-A
Product name: ES type CPU Units with 3
OMRON
CP1E CPU Units
CP1E-N30SDR-A
OMRON CP1E CPU Units CP1E-N30SDR-A
Product name: NS1- type CPU Units with