Applicable CPU Units: CQM1H-CPU51/61.
Serial Communica-tions ports>Port 1: RS-232C: 19.2 kbps max., 15 m max.
Serial Communica-tions ports>Port 2: RS-422A/485: 19.2 kbps max., 500 m max.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
Model : CVM1D-CPU21.
For duplex system requires two CJ2M-MD212 PDF. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection
CJ2M-MD212
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CJ2M-MD212 PDF.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O points: 256 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 3 K.
RS-232C port: YES.Unit type: CS1 Special I/O Units CJ2M-MD212 PDF.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CJ2M-MD212 datasheet.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ2M-MD212 datasheet.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.