Product model: L63SP
Name: Power module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Open collector output.
Axis of control: 1.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft L63SP PDF.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft L63SP
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control L63SP PDF.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created L63SP PDF.
Can import and export the cam data in CSV format. Error output.
Rated open and close voltage, current: DC24V, 0.5A.
Minimum open and close load: DC5V, 1mA.
Response time (OFF, ON): 10ms below.
Response time (ON, OFF): 12ms below.
Life (Mechanical): more than 20 million times.
Life (Electrical) rated open and close voltage, current more than 100 thousand times.
Suitable for wire specifications: 0.3 ~ 2 square mm (AWG22 ~ 14) (twisted pair / single line).
External wiring connection mode: spring clip terminal.
DC5V internal consumption current: 0.06A.
Weight: 0.11kg. Temperature measurement resistor input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use thee control object that does not want to heat up to the time of arrival error L63SP datasheet.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperatture input mode L63SP datasheet.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode.
Related products
MITSUBISHI
Medium inertia power servo motor
HF-SP524B
MITSUBISHI Medium inertia power servo motor HF-SP524B
Servo motor series: medium inertia, medi
MITSUBISHI
Display module
FX3G-5DM
MITSUBISHI Display module FX3G-5DM
Display: 16 characters x 4 lines. Can mo
MITSUBISHI
Medium inertia power servo motor
HF-SP3524
MITSUBISHI Medium inertia power servo motor HF-SP3524
Servo motor series: medium inertia, medi
MITSUBISHI
Medium inertia power servo motor
HF-SP502B
MITSUBISHI Medium inertia power servo motor HF-SP502B
Servo motor series: medium inertia, medi