MITSUBISHI FX2N-4EX-BD datasheet PDF
Product model: FX2N-4EX-BD
Name: Input expansion board
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Can be used as a screw relay terminal.Convert connectors to e-CON.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Function: bus conversion FX5 (connector) - FX3.
Input and output points: 8 points.
Conversion module connecting FX3 series expansion module FX2N-4EX-BD PDF.
FX3 series expansion module, only the right side of the bus conversion module can be connected FX2N-4EX-BD MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 132KW.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc FX2N-4EX-BD PDF. .
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FX2N-4EX-BD PDF. Power: 55kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Power: 7.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FRR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FX2N-4EX-BD datasheet.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FX2N-4EX-BD datasheet.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)
Related products
MITSUBISHI
PLC
FX2N-48MT-D
MITSUBISHI PLC FX2N-48MT-D
Max input / output points: 48 points. Po
MITSUBISHI
PLC
FX2N-64MT-ESS/UL
MITSUBISHI PLC FX2N-64MT-ESS/UL
Max input / output points: 64 points. Su
MITSUBISHI
PLC
FX2N-128MR-D
MITSUBISHI PLC FX2N-128MR-D
Max input / output points: 128 points. S
MITSUBISHI
Adapter adapter
FX2N-CNV-BC
MITSUBISHI Adapter adapter FX2N-CNV-BC
Used in FX0N-30EC or FX0N-65EC type exte