File language: English
Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No AY13C PDF.
Rated load voltage / current: DC24V/AC240V/0.5A.
External connection: 3 line /2 line type AY13C
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AY13C PDF. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC12V/AC240V/2A.
External connection: 2 line /2 line type AY13C PDF.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. 5 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined acccording to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AY13C datasheet.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% AY13C datasheet.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
Bidirectional thyristor output module
AY23C
MITSUBISHI Bidirectional thyristor output module AY23C
Output points: 32 points. Voltage: AC100
MITSUBISHI
Transistor output module
AY80
MITSUBISHI Transistor output module AY80
Output points: 16 points. Voltage: DC12/
MITSUBISHI
Relay output module
AY13EU
MITSUBISHI Relay output module AY13EU
Output points: 32 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11EEU
MITSUBISHI Relay output module AY11EEU
Output points: 16 points. Voltage: DC24V