MITSUBISHI AJ71QE71-B5 datasheet PDF
Product model: AJ71QE71-B5
Name: Ethernet module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
SI/QSI/H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / remote I/O network (remote master station). With external power supply function.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AJ71QE71-B5 PDF AJ71QE71-B5
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of AJ71QE71-B5 PDF.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AJ71QE71-B5 PDF.
This phenomenon is called the I/O delay time effect. Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External cconnection: 3 line /2 line type AJ71QE71-B5 datasheet.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ71QE71-B5 datasheet.
Related products
MITSUBISHI
GI fiber optic cable module
AJ71QLP21G
MITSUBISHI GI fiber optic cable module AJ71QLP21G
GI fier optic cale. Dual loop for Q mo
MITSUBISHI
SI/QSI fiber optic cable module
AJ71QLP21
MITSUBISHI SI/QSI fiber optic cable module AJ71QLP21
SI/QSI/H-PCF/ wide range H-PCF fier opt
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5
MITSUBISHI
Serial communication module
AJ71QC24
MITSUBISHI Serial communication module AJ71QC24
RS-232 1 channel, RS-422/485 1 channel.