MITSUBISHI AJ65SBTC1-32DT3 datasheet PDF
Product model: AJ65SBTC1-32DT3
Name: Fast connector type DC input / output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side AJ65SBTC1-32DT3 PDF.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ65SBTC1-32DT3 PDF AJ65SBTC1-32DT3
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ65SBTC1-32DT3 PDF.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 2~4 line type.
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timmeliness is strong AJ65SBTC1-32DT3 datasheet.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AJ65SBTC1-32DT3 datasheet.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
Transistor output module
AJ65SBTB1-8T
MITSUBISHI Transistor output module AJ65SBTB1-8T
Output type: transistor output, drain ty
MITSUBISHI
Transistor output module
AJ65SBTB1-16TE
MITSUBISHI Transistor output module AJ65SBTB1-16TE
Output type: transistor output, source.
MITSUBISHI
Input module
AJ65SBTB3-16KD
MITSUBISHI Input module AJ65SBTB3-16KD
Input type: DC input, positive pulic en
MITSUBISHI
Transistor output module
AJ65SBTB1-32T
MITSUBISHI Transistor output module AJ65SBTB1-32T
Output type: transistor output, drain ty