MITSUBISHI AJ65SBTC1-32DT datasheet PDF
Product model: AJ65SBTC1-32DT
Name: Fast connector type DC input / output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
32: terminal line adapter 0.75mm2 (AGW18).5 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage AJ65SBTC1-32DT PDF.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load AJ65SBTC1-32DT
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action AJ65SBTC1-32DT PDF.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AJ65SBTC1-32DT PDF.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. Output points: 16 points.
Voltage: DC5/12V.
Output type: Sink type.
Response time: 1ms.
8 points / a common end.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requireements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ65SBTC1-32DT datasheet.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ65SBTC1-32DT datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Transistor output module
AJ65SBTB1-8T1
MITSUBISHI Transistor output module AJ65SBTB1-8T1
Output type: transistor output, drain ty
MITSUBISHI
Transistor output module
AJ65SBTB1B-16TE1
MITSUBISHI Transistor output module AJ65SBTB1B-16TE1
Output type: transistor output, source.
MITSUBISHI
DC input / relay output module
AJ65SBTB32-16KDR
MITSUBISHI DC input / relay output module AJ65SBTB32-16KDR
Input type: DC input, positive / negativ