Product model: AJ35PTF-32A
Name: AC100V input module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 4 points / a public end AJ35PTF-32A PDF.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ35PTF-32A PDF AJ35PTF-32A
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ35PTF-32A PDF.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general,, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AJ35PTF-32A datasheet. A pack of 10.
Applicable models:
AJ65VBTS - - - type. AJ35PTF-32A datasheet.
AJ65VBTCE - - - type.
AJ65VBTCU - - - type.
AJ65ABTP - - - type.
AJ65VBCU- - type.
AJ65SBT-CLB type.
Can only use FANC-110SBH, CS-110, FA-CBL200PSBH.
Related products
MITSUBISHI
DC input module
AJ35PTF-32D
MITSUBISHI DC input module AJ35PTF-32D
DC input points: 32 points. Input voltag
MITSUBISHI
Transistor output module
AJ35PTF-24T
MITSUBISHI Transistor output module
 AJ35PTF-24T
Output points: 24 points. Output voltage
MITSUBISHI
AC input / relay output module
AJ35PTF-28AR
MITSUBISHI AC input / relay output module AJ35PTF-28AR
AC input points: 16 points. Input voltag
MITSUBISHI
Transistor output module
AJ35PJ-8T1
MITSUBISHI Transistor output module
 AJ35PJ-8T1
Output points: 8 points. Output voltage