MITSUBISHI AJ35PP-CNV-GI datasheet PDF
Product model: AJ35PP-CNV-GI
Name: Melsecnet module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours AJ35PP-CNV-GI PDF.
Can be used for each 1 points to enter the wiring of the broken wire detection AJ35PP-CNV-GI
Wiring abnormality of external power supply can be confirmed.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Cable length: 6 meters
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable AJ35PP-CNV-GI PDF. 32 point connector for welding (40 pin connector).3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AJ35PP-CNV-GI PDF.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AJ35PP-CNV-GI datasheet.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic AJ35PP-CNV-GI datasheet.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Melsecnet module
AJ35PP-CNV-GI
MITSUBISHI Melsecnet module AJ35PP-CNV-GI
MELSECNET/MINI -S3 data link system, A
MITSUBISHI
Melsecnet module
AJ35PP-CNV
MITSUBISHI Melsecnet module AJ35PP-CNV
MELSECNET/MINI -S3 data link system, A
MITSUBISHI
Melsecnet module
AJ35PTC-CNV-GI
MITSUBISHI Melsecnet module AJ35PTC-CNV-GI
MELSECNET/MINI -S3 data link system, A
MITSUBISHI
Melsecnet module
AJ35PP-CNV-SI
MITSUBISHI Melsecnet module AJ35PP-CNV-SI
MELSECNET/MINI -S3 data link system, A