MITSUBISHI A2NCPU datasheet PDF
Product model: A2NCPU
Name: CPU unit
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input DAC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Optical data communication line.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way A2NCPU PDF. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A2NCPU
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A2NCPU PDF.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units A2NCPU PDF. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Using a modem middle modular connector unit faces to transmit data transmission speed: 0.3-14.4kbps.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or adddress number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work A2NCPU datasheet A2NCPU datasheet.
Related products
MITSUBISHI
General high speed CPU
Q26UDVCPU
MITSUBISHI General high speed CPU Q26UDVCPU
Input / output points: 4096 points. Inpu
MITSUBISHI
General purpose CPU
Q20UDHCPU
MITSUBISHI General purpose CPU Q20UDHCPU
Specification model: Q20UDHCPU. Input /
MITSUBISHI
Basic type CPU
Q01CPU
MITSUBISHI Basic type CPU Q01CPU
Program capacity: 8K step. Input / outpu
MITSUBISHI
Programmable logic controller CPU
R04CPU
MITSUBISHI Programmable logic controller CPU R04CPU
Operation control mode: stored procedure