MITSUBISHI A2ACPU-S1 datasheet PDF
Product model: A2ACPU-S1
Name: CPU unit
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Long distance bus connection for QCPU.
Applicable models: GT16, GT15, GT11, GT27, GT25. Input points: 32 points.
Voltage: DC12/24V.
Current: 4/10mA.
Response time: 10ms.
8 points / a common end.
Negative utility.
38 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh A2ACPU-S1 PDF.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A2ACPU-S1
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program A2ACPU-S1 PDF.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A2ACPU-S1 PDF.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Output type: transistor source.
Output points: 16 points.
Load voltage: DC12/24.
Load current: 0.8A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combinationn of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A2ACPU-S1 datasheet.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic A2ACPU-S1 datasheet.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Motion controller (upgrade)
Q170MCPU-S1
MITSUBISHI Motion controller (upgrade) Q170MCPU-S1
Axis of control: 16. Compact Q170MCPU in
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
Q2ASCPU-S1
MITSUBISHI CPU unit Q2ASCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2ACPUP21
MITSUBISHI CPU unit A2ACPUP21
Input and output points: 512 points. Inp