MITSUBISHI A1S64TCTRTBW datasheet PDF
Product model: A1S64TCTRTBW
Name: Temperature control module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A1S64TCTRTBW PDF A1S64TCTRTBW
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A1S64TCTRTBW PDF. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A1S64TCTRTBW PDF.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. CC-Link (remote device station).
Twisted pair. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 line /1 line type.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulaation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program A1S64TCTRTBW datasheet A1S64TCTRTBW datasheet.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Temperature control module
A1S64TCRTBW-S1
MITSUBISHI Temperature control module A1S64TCRTBW-S1
Numer of channels: 4 channels Sensing m
MITSUBISHI
Temperature control module
A1S64TCTTBW-S1
MITSUBISHI Temperature control module A1S64TCTTBW-S1
Numer of channels: 4 channels. Sensing
MITSUBISHI
Temperature control module
A1S64TCRT-S1
MITSUBISHI Temperature control module A1S64TCRT-S1
Numer of channels: 4 channels. Sensing
MITSUBISHI
Temperature control module
A1S64TCTRT
MITSUBISHI Temperature control module A1S64TCTRT
The most appropriate temperature regulat