LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
MITSUBISHI A1S38B datasheet PDF
Product model: A1S38B
Name: CPU substrate
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 A1S38B PDF. 5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1S38B
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1S38B PDF. For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 0.5m.A1S68TD is a 8 channel thermocouple input module,
It can receive almost any type of thermocouple input,
Using Ans CPU A1S68TD system can meet the various requirements of process control applications,
Also has the advantages of all aspects of the ANs can provide.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of A1S38B PDF.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect. Input voltage range: DC110V.
Output voltage: DC5V.
Output current: 8A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accoording to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A1S38B datasheet.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A1S38B datasheet.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
Input / output module
A1SH42-S1
MITSUBISHI Input / output module A1SH42-S1
Enter 64 points. Aove DC7V. Response ti
MITSUBISHI
Positioning control module
A1SD75M2
MITSUBISHI Positioning control module A1SD75M2
Axis of control: 2. Interpolation functi
MITSUBISHI
Thermocouple Input Module
A1S68TD
MITSUBISHI Thermocouple Input Module A1S68TD
A1S68TD is a 8 channel thermocouple inpu