LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Catalog Download
OMRON KS1-ANDC10 datasheet PDF
Product model: KS1-ANDC10
Name: Ionizer
Brand: OMRON
Sort: PDF datasheet
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element KS1-ANDC10 PDF.
Burnout Detector compatible with a,
wide-range of heater control methods KS1-ANDC10
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance KS1-ANDC10 PDF.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note KS1-ANDC10 PDF. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervolltages KS1-ANDC10 datasheet.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported KS1-ANDC10 datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Ionizer
KS1-AZ02
OMRON Ionizer KS1-AZ02
Product: Tool for Replacing Dischargers.
OMRON
Ionizer
KS1-ANDC20
OMRON Ionizer KS1-ANDC20
Product: Flexile Tue Nozzle 200 mm.
OMRON
Ionizer
KS1-ANNS-S
OMRON Ionizer KS1-ANNS-S
Product: 500-mm Silicone Tue. Wide Ran
OMRON
Ionizer
KS1-ANDC10
OMRON Ionizer KS1-ANDC10
Product: Flexile Tue Nozzle 100 mm.