Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 1000mm; B, 750mm.
Input use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable G9SA-321-T075-300 PDF. Structure: single stable type.
Contact structure: 1a.
Structure: high flux protection.
Coil rated voltage: DC18V.
Voltage resistant 10kV 1 pole 3A open close small relay
G9SA-321-T075-300
High power electromagnetic loop is used to achieve high sensitivity (200mW).
Small relays, but can ensure the impact resistance of 10kV. Type: input module.
Insulation: photo coupler.
Action indicator: there G9SA-321-T075-300 PDF.
Logic supply voltage: DC4 ~ 32V.
Logic supply current: 25mA.
Input rated voltage: AC100 ~ 240V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal G9SA-321-T075-300 PDF. Can also be mixed with the I/O type G7T relay.
Can check the workking status of SSR through the action indicator G9SA-321-T075-300 Manual.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Contact form: 4PDT.
Classification: Standard model OMRON user's manual.
Plug-in terminals.
Fully Sealed Version of G2A that Displays Its.
Power in Adverse Environments.
Exhibits stable performance in an adverse atmosphere of,
harmful gas, moisture, or powdery dust due to its hermetically,
sealed construction.
All the mechanical components of the Relay have been,
annealed to prevent gas generation inside the Relay OMRON user's manual.
Economical as compared with a hermetically sealed relay in a,
metallic enclosure. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max OMRON user's manual.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts. G9SA-321-T075-300 user's manual.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software G9SA-321-T075-300 Manual.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.