Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog(current/voltage).
Alarm output: 2.
option units Mounting: Yes E6F-AB5B PDF.
Control output: Current output.
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders
E6F-AB5B
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled E6F-AB5B PDF.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 10 dia E6F-AB5B PDF.
Protective tubing length L: 50 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M8 connector (3-pin).
Body mmaterial: Stainless steel OMRON INSTRUCTION sheet E6F-AB5B Manual.
Thread length (overall length): 27 (39).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated OMRON INSTRUCTION sheet.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increassed,
Further performance improvement E6F-AB5B INSTRUCTION sheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E6F-AB5B Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.